4.6 Article

Consideration of some sampling problems in the on-line analysis of batch processes by low-field NMR spectrometry

期刊

ANALYST
卷 133, 期 3, 页码 339-347

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/b714266h

关键词

-

向作者/读者索取更多资源

A low-field medium- resolution NMR spectrometer, with an operating frequency of 29 MHz for H-1, has been assessed for on-line process analysis. A flow cell that incorporates a pre-magnetisation region has been developed to minimise the decrease in the signal owing to incomplete polarisation effects. The homogeneous esterification reaction of crotonic acid and 2-butanol was monitored using a simple sampling loop; it was possible to monitor the progression of the reaction through changes in CH signal areas of butanol and butyl crotonate. On-line analysis of heterogeneous water-toluene mixtures proved more challenging and a fast sampling loop system was devised for use with a 5 L reactor. The fast sampling loop operated at a flow rate of 8 L min(-1) and a secondary sampling loop was used to pass a sub-sample through the NMR analyser at a slower (mL min(-1)) rate. It was shown that even with super-isokinetic sampling conditions, unrepresentative sampling could occur owing to inadequate mixing in the reactor. However, it was still possible to relate the H-1 NMR signal obtained at a flow rate of 60 mL min(-1) to the composition of the reactor contents.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据