4.6 Article

Cold Machine Perfusion Versus Static Cold Storage of Kidneys Donated After Cardiac Death: A UK Multicenter Randomized Controlled Trial

期刊

AMERICAN JOURNAL OF TRANSPLANTATION
卷 10, 期 9, 页码 1991-1999

出版社

WILEY
DOI: 10.1111/j.1600-6143.2010.03165.x

关键词

Cardiac death donors; machine preservation; kidney preservation; kidney transplantation

资金

  1. Novartis Pharmaceuticals UK
  2. Organ Recovery Systems

向作者/读者索取更多资源

One third of deceased donor kidneys for transplantation in the UK are donated following cardiac death (DCD). Such kidneys have a high rate of delayed graft function (DGF) following transplantation. We conducted a multicenter, randomized controlled trial to determine whether kidney preservation using cold, pulsatile machine perfusion (MP) was superior to simple cold storage (CS) for DCD kidneys. One kidney from each DCD donor was randomly allocated to CS, the other to MP. A sequential trial design was used with the primary endpoint being DGF, defined as the necessity for dialysis within the first 7 days following transplant. The trial was stopped when data were available for 45 pairs of kidneys. There was no difference in the incidence of DGF between kidneys assigned to MP or CS (58% vs. 56%, respectively), in the context of an asystolic period of 15 min and median cold ischemic times of 13.9 h for MP and 14.3 h for CS kidneys. Renal function at 3 and 12 months was similar between groups, as was graft and patient survival. For kidneys from controlled DCD donors (with mean cold ischemic times around 14 h), MP offers no advantage over CS, which is cheaper and more straightforward.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据