4.6 Article

Diagnostic Ability of Fourier-Domain vs Time-Domain Optical Coherence Tomography for Glaucoma Detection

期刊

AMERICAN JOURNAL OF OPHTHALMOLOGY
卷 148, 期 4, 页码 597-605

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ajo.2009.05.030

关键词

-

资金

  1. MALTZ FAMILY ENDOWMENT FOR GLAUCOMA RESEARCH, CLEVELAND, OHIO
  2. Palm Beach, Florida
  3. Kessel Foundation, Bergenfield, New Jersey
  4. National Institutes of Health, Bethesda, Maryland [R01-EY08684, R01-EY013516, P30-EY14801]
  5. Research to Prevent Blindness Inc, New York, New York

向作者/读者索取更多资源

PURPOSE: To compare retinal nerve fiber layer (RNFL) thickness assessments and the discriminating ability of Fourier-domain optical coherence tomography (FD-OCT) with that of time,domain optical coherence tomography (TD-OCT) for glaucoma detection. DESIGN: Prospective, nonrandomized, observational cohort study. METHODS: Normal and glaucomatous eyes underwent complete examination, standard automated perimetry, optic disc photography, TD-OCT (Stratus OCT; Carl Zeiss Meditec, Dublin, California, USA), and FD-OCT (RTVue; Optovue Inc, Fremont, California, USA). One eye per subject was enrolled. Two consecutive scans were acquired using a 3.46-mm diameter scan with TD-OCT and a 3.45 mm diameter scan with FD-OCT. For each of 5 RNFL parameters, the area under the receiver operator characteristic curve was calculated to compare the ability of FD-OCT and TD-OCT to discriminate between nor. mal and glaucomatous eyes.. 9 RESULTS: Fifty healthy persons (mean age, 65.3 +/- 9.9 years) and 50 glaucoma patients (mean age, 67.7 +/- 10.5 years) were enrolled. Average, superior, and inferior RNFL thickness measurements (in micrometers) were significantly (P < .01) greater with FD-OCT compared with TD-OCT in normal eyes (103.3 +/- 12.6 vs 96.3 +/- 10.7, 134.5 +/- 18.6 vs 113.9 +/- 16.3, and 129.7 +/- 16.9 vs 125.5 +/- 15.8, respectively) and glaucomatous eyes (P < .001; 77.6 +/- 17.6 vs 70.4 +/- 18.6, 108.0 +/- 26.8 vs 86.8 +/- 30.2, 82.2 +/- 3.3 vs 73.5 +/- 26.1, respectively). The area under the receiver operator characteristic curves for RNFL thickness were similar (P > .05) using FD-OCT (average, 0.88; superior, 0.80; inferior, 0.94) and TD-OCT (average, 0.87; superior, 0.79; inferior, 0.95). CONCLUSIONS: Cross,sectional peripapillary RNFL thickness measurements obtained using FD-OCT generated with the RTVue are greater than those obtained with TD-OCT and have similar diagnostic performance for glaucoma detection. (Am J Ophthalmol 2009;148: 597-605. (C) 2009 by Elsevier Inc. All rights reserved.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据