4.6 Article

First-trimester placental ultrasound and maternal serum markers as predictors of small-for-gestational-age infants

期刊

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.ajog.2014.02.033

关键词

3-dimensional ultrasound; fetal growth restriction; placenta; placental growth factor; uterine artery Doppler

资金

  1. Penn Presbyterian George L. and Emily McMichael Harrison Fund for Research in Obstetrics and Gynecology
  2. [1R03HD069742-01A1]

向作者/读者索取更多资源

OBJECTIVE: The objective of the study was to combine early, direct assessment of the placenta with indirect markers of placental development to identify pregnancies at greatest risk of delivering small-for-gestational age infants (SGA10). STUDY DESIGN: We prospectively collected 3-dimensional ultrasound volume sets, uterine artery pulsatility index, and maternal serum of singleton pregnancies at 11-14 weeks. Placental volume (PV), quotient (placental quotient [PQ] = PV/gestational age), mean placental diameter (MPD) and chorionic diameters, and the placental morphology index (PMI = MPD/PQ and adjusts the lateral placental dimensions for quotient) were measured offline. Maternal serum was assayed for placental growth factor and placental protein-13. These variables were evaluated as predictors of SGA10. RESULTS: Of the 578 pregnancies included in the study, 56 (9.7%) delivered SGA10. SGA10 pregnancies had a significantly smaller PV, PQ, MPD, and mean placental diameter and higher PMI compared with normal pregnancies (P < .001 for each). Each placental measure remained significantly associated with SGA10 after adjusting for confounders and significantly improved the performance of the model using clinical variables alone (P < .04 for each) with adjusted areas under the curve ranging from 0.71 to 0.74. Uterine artery pulsatility index did not remain significantly associated with SGA10 after adjusting for confounders (P = .06). Placental growth factor was significantly lower in SGA10 pregnancies (P = .02) and remained significant in adjusted models but failed to significantly improve the predictive performance of the models as measured by area under the curve (P > .3). Placental protein-13 was not associated with SGA10 (P - .99). CONCLUSION: Direct assessment of placental size and shape with 3-dimensional ultrasound can serve as the foundation upon which to build a multivariable model for the early prediction of SGA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据