4.6 Article

Vastus lateralis surface and single motor unit electromyography during shortening, lengthening and isometric contractions corrected for mode-dependent differences in force-generating capacity

期刊

ACTA PHYSIOLOGICA
卷 196, 期 3, 页码 315-328

出版社

WILEY-BLACKWELL PUBLISHING, INC
DOI: 10.1111/j.1748-1716.2008.01941.x

关键词

dynamic contractions; torque-velocity relationship; voluntary activation

向作者/读者索取更多资源

Knee extensor neuromuscular activity, rectified surface electromyography (rsEMG) and single motor unit EMG was investigated during isometric (60 degrees knee angle), shortening and lengthening contractions (50-70 degrees, 10 degrees s(-1)) corrected for force-velocity-related differences in force-generating capacity. However, during dynamic contractions additional factors such as shortening-induced force losses and lengthening-induced force gains may also affect force capacity and thereby neuromuscular activity. Therefore, even after correction for force-velocity-related differences in force capacity we expected neuromuscular activity to be higher and lower during shortening and lengthening, respectively, compared to isometric contractions. rsEMG of the three superficial muscle heads was obtained in a first session [10 and 50% maximal voluntary contraction (MVC)] and additionally EMG of (46) vastus lateralis motor units was recorded during a second session (4-76% MVC). Using superimposed electrical stimulation, force-generating capacity for shortening and lengthening contractions was found to be 0.96 and 1.16 times isometric (Iso) force capacity respectively. Therefore, neuromuscular activity during submaximal shortening and lengthening was compared with isometric contractions of respectively 1.04Iso (=1/0.96) and 0.86Iso (=1/1.16). rsEMG and discharge rates were normalized to isometric values. rsEMG behaviour was similar (P > 0.05) during both sessions. Shortening rsEMG (1.30 +/- 0.11) and discharge rate (1.22 +/- 0.13) were higher (P < 0.05) than 1.04Iso values (1.05 +/- 0.05 and 1.03 +/- 0.04 respectively), but lengthening rsEMG (1.05 +/- 0.12) and discharge rate (0.90 +/- 0.08) were not lower (P > 0.05) than 0.86Iso values (0.76 +/- 0.04 and 0.91 +/- 0.07 respectively). When force-velocity-related differences in force capacity were taken into account, neuromuscular activity was not lower during lengthening but was still higher during shortening compared with isometric contractions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据