期刊
ACTA BIOMATERIALIA
卷 4, 期 6, 页码 1745-1751出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.actbio.2008.06.013
关键词
Plasma polymer; Sterilization; Cell adhesion; Anti-adhesive surface; XPS
资金
- European Commission [515859-2]
The influence of several sterilization processes (autoclaving, gamma-ray irradiation, ethylene oxide exposure and Ar/H-2 low pressure plasma treatment) on the surface chemistry and the bioadhesive properties of thin films (thickness similar to 20 nm) of plasma-polymerized diethylene glycol dimethyl ether has been studied. X-ray photoelectron spectroscopy (XPS) analysis and cell proliferation tests were used to characterize the surfaces. The XPS results revealed in all cases a change in the surface chemistry of the layer after sterilization, whereas the conservation of non-bioadhesive properties of the coating depends on the type of sterilization process. In particular, the low pressure plasma-based sterilization technique leads to a loss of the non-bioadhesive properties of the plasma coating, whereas the coatings are resistant to the other standard decontamination techniques. This property makes them suitable for biomedical applications, provided that an appropriate sterilization process is selected. (C) 2008 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。