4.6 Article

Experimental Study on the Fire Performance of Tubular Steel Columns with Membrane Protections for Prefabricated and Modular Steel Construction

期刊

MATERIALS
卷 11, 期 3, 页码 -

出版社

MDPI
DOI: 10.3390/ma11030437

关键词

hollow structural section (HSS); steel tubular column; axial load; prefabricated and modular construction; membrane protection

资金

  1. National Natural Science Foundation of China [51676210]
  2. Fundamental Research Funds for the Central Universities of Central South University [2013zzts049]
  3. Natural Science Foundation of Hunan Province of China [2017JJ3392]
  4. Ministry of Public Security [201302ZDYJ014]
  5. China Postdoctoral Science Foundation [2016M602430]

向作者/读者索取更多资源

Experimental research was conducted to study the fire resistance of steel tubular columns used in prefabricated and modular construction. In order to achieve high-efficient prefabrication and fast on-site installation, membrane protections using board products and thermal insulation blankets are adopted as the favorable protection method. Three protected tubular columns were tested in a full-scale column furnace with axial load applied. The study variables were different membranes, including fiber reinforced calcium silicate (FRCS) boards, rock wool and aluminum silica (Fiberfrax) insulations. The results suggest that one layer of 12 mm FRCS board with rock wool insulation has insufficient fire protection. However, steel columns protected with two layers of 12 mm FRCS boards with insulation appeared to have good fire resistances and could achieve a fire resistance rating as high as 2.5 similar to 3.0 h.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据