4.7 Article

A model for predicting smoke back-layering length in tunnel fires with the combination of longitudinal ventilation and point extraction ventilation in the roof

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.tust.2018.05.022

关键词

Tunnel fire; Longitudinal ventilation; Point extraction; Back-layering length

资金

  1. National Natural Science Funds of China [51576144, 51508426]
  2. China Scholarship Council [201506270067]

向作者/读者索取更多资源

An analytical model is developed for quantifying the fire smoke back-layering length in a tunnel with a combination of longitudinal ventilation and point extraction ventilation in the roof. The distance of smoke vent to fire source is incorporated as well as mass flow rate during the whole smoke flow process according to the mass conservation principle. The model input quantities are the heat release rate of the fire source, the longitudinal velocity, the exhaust velocity, the width and the height of the tunnel, the distance of the smoke vent to the fire source and the area of the smoke vent. The quality of the model predictions is illustrated for a range of experimental conditions. After that, extensive model predictions on the back layering length are presented to show its trends by varying the velocity of the longitudinal ventilation, the exhaust velocity and the position of the smoke vent in the roof. Discussions are given at last. It is highlighted that shortening the distance between the smoke vent and the fire source benefits shortening the back-layering length, and this phenomenon is more pronounced for higher exhaust velocity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据