4.7 Article

Potentiometric textile-based pH sensor

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 260, 期 -, 页码 601-608

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2018.01.002

关键词

pH sensor; EIROF; Nanostructured electrode; Wearable; Athletes monitoring

向作者/读者索取更多资源

Determining the pH of sweat provides valuable information for athletes and patient monitoring. This work presents a textile-based, highly sensitive pH sensor for pH determination. Three conductive fabrics (Argenmesh, Ristop silver and stainless steel mesh (SSM)) were modified with a pH sensitive electrode posited iridium oxide film (EIROF). The three electrodeposited fabrics were characterized by impedance measurements. The stainless steel mesh showed the best sensitivity to pH changes and therefore was selected for further experiments. Two configurations of this fabric were evaluated, looking for improvement in pH sensitivity and temperature dependence. The best result was obtained with the configuration that maximizes the contact surface between the stainless steel fibers, showing an error of 0.15% in the pH measurement of a buffer solution. This configuration was also used to perform in vivo measurements, obtaining an error of 4% when compared to the measurements performed with a commercial pH test strip. The implementation of sensor into textiles brings some advantages such as comfort, biocompatibility and washability, among others; making the future incorporation of a sensor into a garment very possible. (C) 2018 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据