Uncertainty analysis on droplet size measurement in dispersed flow film boiling regime during reflood using image processing technique

期刊

NUCLEAR ENGINEERING AND DESIGN
卷 326, 期 -, 页码 202-219

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.nucengdes.2017.11.013

关键词

DFFB; Droplet; Image processing; Sample size; Uncertainty interval

资金

  1. U.S. Nuclear Regulatory Commission [NRC-HQ-60-16-T-0002]

向作者/读者索取更多资源

In the dispersed flow film boiling (DFFB) regime during the reflood stage of a postulated loss of coolant accident (LOCA), liquid droplets are entrained by a continuous vapor phase moving upward within the rod bundle. The liquid droplets may interact strongly with the vapor flow and the resulting thermal-hydraulic behavior of the two-phase mixture could significantly affect the evolution of peak cladding temperature (PCT). Therefore, a clear and comprehensive understanding of liquid droplet behavior is crucial for reactor safety analysis. As an attempt to visualize and quantify the droplet behavior during reflood, an advanced image processing technique is used in the present study to capture the distributions of droplet size and velocity at the RBHT test facility. In order to ensure that the experimental droplet data obtained is reliable as well as to better utilize the data for subsequent thermal-hydraulic analyses, the image processing based measurement uncertainties have to be investigated and analyzed. In this paper, various statistical methods are explored to determine the minimum droplet sample size required as a function of standard deviation at a given confidence level. Accordingly, an appropriate droplet count lower limit is selected. Based on this lower limit, the 95% confidence intervals are determined for two typical reflood tests. In addition, the repeatability in droplet measurement of Rod Bundle Heat Transfer (RBHT) reflood tests is carefully examined by comparing data sets from two identical tests. Results show that a lower required level of precision and a smaller scattering in the measured droplet data generally require a smaller sample size. For typical RBHT reflood tests, it is found that the droplet size measured downstream of a spacer grid near the peak power location always has better accuracy compared with that at the upstream location. For the tests investigated, the maximum relative error in the liquid droplet Sauter mean diameter is found to be generally smaller than 0.15 (15%) when the droplet count lower limit is 30. Comparison of the results from two identical tests indicates that the RBHT reflood test results are highly repeatable.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据