4.5 Article

Potentiodynamic polarization study of the corrosion behavior of palladium-silver dental alloys

期刊

JOURNAL OF PROSTHETIC DENTISTRY
卷 119, 期 4, 页码 650-656

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.prosdent.2017.06.026

关键词

-

资金

  1. National Institute of Dental and Craniofacial Research [DE10147]

向作者/读者索取更多资源

Statement of problem. Although palladium-silver alloys have been marketed for over 3 decades for metal-ceramic restorations, understanding of the corrosion behavior of current alloys is incomplete; this understanding is critical for evaluating biocompatibility and clinical performance. Purpose. The purpose of this in vitro study was to characterize the corrosion behavior of 3 representative Pd-Ag alloys in simulated body fluid and oral environments and to compare them with a high-noble Au-Pd alloy. The study obtained values of important electrochemical corrosion parameters, with clinical relevance, for the rational selection of casting alloys. Material and methods. The room temperature in vitro corrosion characteristics of the 3 Pd-Ag alloys and the high-noble Au-Pd alloy were evaluated in 0.9% NaCI, 0.09% NaCI, and Fusayama solutions. After simulated porcelain firing heat treatment, 5 specimens of each alloy were immersed in the electrolytes for 24 hours. For each specimen, the open-circuit potential (OCP) was first recorded, and linear polarization was then performed from -20 mV to +20 mV (versus OCP) at a rate of 0.125 mV/s. Cyclic polarization was subsequently performed on 3 specimens of each alloy from -300 mV to +1000 mV and back to -300 mV (versus OCP) at a scanning rate of 1 mV/s. The differences in OCP and corrosion resistance parameters (zero-current potential and polarization resistance) among alloys and electrolyte combinations were compared with the 2-factor ANOVA (maximum-likelihood method) with post hoc Tukey adjustments (alpha=.05). Results. The 24-hour OCPs and polarization resistance values of the 3 Pd-Ag alloys and the Au-Pd alloy were not significantly different (P=.233 and P=.211, respectively) for the same electrolyte, but significant differences were found for corrosion test results in different electrolytes (P<.001 and P=.032, respectively). No significant interaction was found between the factors of alloy and electrolyte (P=.249 and P=.713, respectively). The 3 Pd-Ag silver alloys appeared to be resistant to chloride ion corrosion, and passivation and de-alloying were identified for these alloys. Conclusions. The Pd-Ag alloys test results showed excellent in vitro corrosion resistance and were equivalent to those of the high-noble Au-Pd alloy in simulated body fluid and oral environments. Passivation, de-alloying, and formation of a AgCI layer were identified as possible corrosion mechanisms for Pd-Ag alloys.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据