4.4 Article

Magnetic circuit analysis to obtain the magnetic permeability of magnetorheological elastomers

期刊

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/1045389X18781046

关键词

Magnetorheological elastomer; magnetic permeability; magnetic circuit; magnetic induction

向作者/读者索取更多资源

The magnetic permeability of magnetorheological elastomers must be known for their long-term use in the actual engineering systems. In this article, the magnetic permeability of both isotropic and anisotropic magnetorheological elastomers has been determined using a new method. The magnetic induction was measured and a closed magnetic circuit analysis was carried out to obtain the magnetic permeability of magnetorheological elastomers for both isotropic and anisotropic magnetorheological elastomers with 10%-50% volume concentration of carbonyl iron particles. The magnetic permeability was increased with increasing particle concentration for both isotropic and anisotropic magnetorheological elastomers as we could expect. The isotropic permeability is always lower than the anisotropic permeability. The maximum relative permeability value of 6.6 was obtained for 50% particle volume concentration. The experimental results also show a good agreement with theoretical predictions and previous investigations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据