Is there an association between airborne and surface microbes in the critical care environment?

期刊

JOURNAL OF HOSPITAL INFECTION
卷 100, 期 3, 页码 E123-E129

出版社

W B SAUNDERS CO LTD
DOI: 10.1016/j.jhin.2018.04.003

关键词

Hospital-acquired infection; Hospital environment; Air; Bacterial transmission; Environmental contamination; Staphylococcus aureus; MRSA

资金

  1. NHS Lanarkshire
  2. Edinburgh Napier
  3. Leeds Universities, UK

向作者/读者索取更多资源

Background: There are few data and no accepted standards for air quality in the intensive care unit (ICU). Any relationship between airborne pathogens and hospital-acquired infection (HAI) risk in the ICU remains unknown. Aim: First, to correlate environmental contamination of air and surfaces in the ICU; second, to examine any association between environmental contamination and ICU-acquired staphylococcal infection. Methods: Patients, air, and surfaces were screened on 10 sampling days in a mechanically ventilated 10-bed ICU for a 10-month period. Near-patient hand-touch sites (N = 500) and air (N = 80) were screened for total colony count and Staphylococcus aureus. Air counts were compared with surface counts according to proposed standards for air and surface bioburden. Patients were monitored for ICU-acquired staphylococcal infection throughout. Findings: Overall, 235 of 500 (47%) surfaces failed the standard for aerobic counts (<= 2.5 cfu/cm(2)). Half of passive air samples (20/40: 50%) failed the 'index of microbial air' contamination (2 cfu/9 cm plate/h), and 15/40 (37.5%) active air samples failed the clean air standard (<10 cfu/m(3)). Settle plate data were closer to the pass/fail proportion from surfaces and provided the best agreement between air parameters and surfaces when evaluating surface benchmark values of 0-20 cfu/cm(2) . The surface standard most likely to reflect hygiene pass/fail results compared with air was 5 cfu/cm(2) . Rates of ICU-acquired staphylococcal infection were associated with surface counts per bed during 72 h encompassing sampling days (P = 0.012). Conclusion: Conclusion: Passive air sampling provides quantitative data analogous to that obtained from surfaces. Settle plates could serve as a proxy for routine environmental screening to determine the infection risk in ICU. (C) 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据