Effect of the wick characteristics on the thermal behaviour of a LHP capillary evaporator

期刊

INTERNATIONAL JOURNAL OF THERMAL SCIENCES
卷 133, 期 -, 页码 22-31

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.ijthermalsci.2018.07.003

关键词

Loop heat pipe evaporator; Sintered copper wick; Hydrodynamic characteristics; Heat transfer coefficient; Capillary limit; Boiling limit; Water; Pentane

向作者/读者索取更多资源

The present work aims at investigating the effect of the characteristics of porous wicks integrated in a flat disk-shaped LHP evaporator on their thermal performance and operating limits. Several wicks were manufactured by sintering of copper powder following a design of experiment, and characterised in terms of permeability, porosity, pore radius and thickness. A specific test bench was designed, consisting of a LHP evaporator uncoupled from the condenser. Water and pentane were used as the working fluids. The theoretical capillary and boiling limits of the wicks in the test bench were studied and compared to the experimental data. It was observed that a high permeable wick (K > 10(-13) m(2)) is likely to reach the boiling limit before the capillary limit because the fluid easily percolates through it. The heat transfer coefficient between the evaporator wall and the evaporating fluid is significantly higher with pentane than with water. It reaches a maximum value of 2340 W m(-2). K-1 with water and 5310 W m(-2). K -1 with pentane, but no clear tendency could be highlighted concerning the effect of the wick characteristics on this parameter. The maximum dissipated heat transfer rate before the wick dry-out varies in a smaller range with pentane than with water. The highest measured values are equal to 88 kW m(-2) with water and 56 kW m(-2 )with pentane.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据