4.7 Review

Systematic review on bedside electromagnetic-guided, endoscopic, and fluoroscopic placement of nasoenteral feeding tubes

期刊

GASTROINTESTINAL ENDOSCOPY
卷 81, 期 4, 页码 836-+

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.gie.2014.10.040

关键词

-

向作者/读者索取更多资源

Background: Nasoenteral tube feeding is frequently required in hospitalized patients to either prevent or treat malnutrition, but data on the optimal strategy of tube placement are lacking. Objective: To compare the efficacy and safety of bedside electromagnetic (EM)-guided, endoscopic, and fluoroscopic placement of nasoenteral feeding tubes in adults. Design: Systematic review of the literature. Patients: Adult hospitalized patients requiring nasoenteral feeding. Interventions: EM-guided, endoscopic, and/or fluoroscopic nasoenteral feeding tube placement. Main Outcome Measurements: Success rate of tube placement and procedure-or tube-related adverse events. Results: Of 354 screened articles, 28 studies were included. Data on 4056 patients undergoing EM-guided (n = 2921), endoscopic (n = 730), and/or fluoroscopic (n = 405) nasoenteral feeding tube placement were extracted. Tube placement was successful in 3202 of 3789 (85%) EM-guided procedures compared with 706 of 793 (89%) endoscopic and 413 of 446 (93%) fluoroscopic procedures. Reinsertion rates were similar for EM-guidance (270 of 1279 [21%] patients) and endoscopy (64 of 394 [16%] patients) or fluoroscopy (10 of 38 [26%] patients). The mean (standard deviation) procedure time was shortest with EM-guided placement (13.4 [12.9] minutes), followed by endoscopy and fluoroscopy (14.9 [8.7] and 16.2 [23.6] minutes, respectively). Procedure-related adverse events were infrequent (0.4%, 4%, and 3%, respectively) and included mainly epistaxis. The tube-related adverse event rate was lowest in the EM-guided group (36 of 242 [15%] patients), followed by fluoroscopy (40 of 191 [21%] patients) and endoscopy (115 of 384 [30%] patients) and included mainly dislodgment and blockage of the tube. Limitations: Heterogeneity and limited methodological quality of the included studies. Conclusion: Bedside EM-guided placement of nasoenteral feeding tubes appears to be as safe and effective as fluoroscopic or endoscopic placement. EM-guided tube placement by nurses may be preferred over more costly procedures performed by endoscopists or radiologists, but randomized studies are lacking.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据