4.4 Article

Sensing Characteristic of Arrayed Flexible Indium Gallium Zinc Oxide Lactate Biosensor Modified by GO and Magnetic Beads

期刊

IEEE TRANSACTIONS ON NANOTECHNOLOGY
卷 17, 期 1, 页码 147-153

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNANO.2017.2782756

关键词

Indium gallium zinc oxide (IGZO); Graphene oxide; Magnetic bead; Microfluidic device; Electrochemical impedance spectroscopy

资金

  1. Ministry of Science and Technology, Republic of China [MOST 105-2221-E-224-049, MOST 105-2815-C-224-022-E, MOST 106-2221-E224-047]

向作者/读者索取更多资源

In this study, the arrayed flexible indium gallium zinc oxide (IGZO) lactate biosensor was modified by graphene oxide (GO) and magnetic beads (MB). The biosensor has arrayed structure with six sensing windows. The arrayed structure with six IGZO windows was fabricated by using radio frequency sputtering system and screen-printed technology. The lactate enzyme was combined with GO and MB, and which was immobilized on the IGZO windows by the crossing-link method. The GO and MB could enhance the average sensitivity of the lactate biosensor, and the optimal content was also investigated. After that, the lactate biosensor was integrated in the microfluidic device, and the average sensitivity also could be enhanced by controlling the flowrate of test solution. Furthermore, the electrochemical reaction of different sensing films could be described by electrochemical impedance spectroscopy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据