期刊
COMPOSITE STRUCTURES
卷 187, 期 -, 页码 226-240出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.compstruct.2017.12.051
关键词
Fiber reinforced polymers (FRP); Fire resistance; FRP strengthened slab; Numerical model; Reinforced concrete (RC) slab
资金
- Michigan State University
- Michigan State University
A numerical model for evaluating the performance of fiber-reinforced polymer (FRP) strengthened reinforced concrete (RC) slabs under fire conditions is presented. The numerical model utilizes a macroscopic finite element based approach to trace thermo-mechanical response of FRP-strengthened RC slabs from linear elastic stage to collapse under fire conditions. The model accounts for temperature dependent properties of concrete, steel, FRP, and fire insulation as well as for temperature induced degradation of bond between concrete and FRP. The model is validated by comparing predicted response of FRP strengthened RC slabs with measured temperatures and deflections in fire tests. A case study is also presented to compare fire performance of RC slabs with and without FRP strengthening, as well as with different insulation and bond configurations. Results from the analysis indicate that a FRP strengthened RC slab, without any fire insulation, yields lower fire resistance as compared to conventional RC slab. Also, temperature induced bond degradation significantly influences fire performance of an FRP strengthened RC slab and neglecting bond degradation may lead to un-conservative estimation of fire resistance.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐