4.3 Article

Limited Sampling Strategy for Accurate Prediction of Pharmacokinetics of Saroglitazar: A 3-point Linear Regression Model Development and Successful Prediction of Human Exposure

期刊

CLINICAL THERAPEUTICS
卷 40, 期 3, 页码 456-468

出版社

ELSEVIER
DOI: 10.1016/j.clinthera.2018.01.016

关键词

bias; BlandAltman; limited sampling; precision; regression; saroglitazar

资金

  1. Cadila Healthcare Limited, a Zydus Group Company (Ahmedabad, Gujarat, India)

向作者/读者索取更多资源

Purpose: Our aim was to develop and validate the extrapolative performance of a regression model using a limited sampling strategy for accurate estimation of the area under the plasma concentration versus time curve for saroglitazar. Methods: Healthy subject pharmacokinetic data from a well-powered food-effect study (fasted vs fed treatments; n = 50) was used in this work. The first 25 subjects' serial plasma concentration data up to 72 hours and corresponding AUC(0-t) (ie, 72 hours) from the fasting group comprised a training dataset to develop the limited sampling model. The internal datasets for prediction included the remaining 25 subjects from the fasting group and all 50 subjects from the fed condition of the same study. The external datasets included pharmacokinetic data for saroglitazar from previous single-dose clinical studies. Limited sampling models were composed of 1-, 2-, and 3-concentration-time points' correlation with AUC(0-t) of saroglitazar. Only models with regression coefficients (R-2) > 0.90 were screened for further evaluation. The best R-2 model was validated for its utility based on mean prediction error, mean absolute prediction error, and root mean square error. Both correlations between predicted and observed AUC(0-t) of saroglitazar and verification of precision and bias using Bland-Altman plot were carried out. Findings: None of the evaluated 1- and 2-concentration-time points models achieved R-2 > 0.90. Among the various 3-concentration-time points models, only 4 equations passed the predefined criterion of R-2 > 0.90. Limited sampling models with time points 0.5, 2, and 8 hours (R-2 = 0.9323) and 0.75, 2, and 8 hours (R-2 = 0.9375) were validated. Mean prediction error, mean absolute prediction error, and root mean square error were <30% (predefined criterion) and correlation (r) was at least 0.7950 for the consolidated internal and external datasets of 102 healthy subjects for the AUC(0-t) prediction of saroglitazar. The same models, when applied to the AUC(0-t) prediction of saroglitazar sulfoxide, showed mean prediction error, mean absolute prediction error, and root mean square error <30% and correlation (r) was at least 0.9339 in the same pool of healthy subjects. (C) 2018 Elsevier HS Journals, Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据