4.5 Article

How Accurate Is Inverse Electrocardiographic Mapping? A Systematic In Vivo Evaluation

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCEP.117.006108

关键词

arrhythmias, cardiac; electrocardiography; epicardial mapping; magnetic resonance imaging; torso

资金

  1. Health Research Council of New Zealand Programme [09/067]
  2. European grant MSCA CORDIS 3D [IRSES-GA-2013-317767]
  3. French government, Investments of the Future program [ANR-10-IAHU-04]
  4. fondation Leducq through the RHYTHM transatlantic network [RG 16CVD02]
  5. University of Auckland Doctoral Scholarship

向作者/读者索取更多资源

BACKGROUND: Inverse electrocardiographic mapping reconstructs cardiac electrical activity from recorded body surface potentials. This noninvasive technique has been used to identify potential ablation targets. Despite this, there has been little systematic evaluation of its reliability. METHODS: Torso and ventricular epicardial potentials were recorded simultaneously in anesthetized, closed-chest pigs (n=5), during sinus rhythm, epicardial, and endocardial ventricular pacing (70 records in total). Body surface and cardiac electrode positions were determined and registered using magnetic resonance imaging. Epicardial potentials were reconstructed during ventricular activation using experiment-specific magnetic resonance imaging-based thorax models, with homogeneous or inhomogeneous (lungs, skeletal muscle, fat) electrical properties. Coupled finite/boundary element methods and a meshless approach based on the method of fundamental solutions were compared. Inverse mapping underestimated epicardial potentials > 2-fold (P<0.0001). RESULTS: Mean correlation coefficients for reconstructed epicardial potential distributions ranged from 0.60 +/- 0.08 to 0.64 +/- 0.07 across all methods. Epicardial electrograms were recovered with reasonable fidelity at approximate to 50% of sites (median correlation coefficient, 0.69-0.72), but variation was substantial. General activation spread was reproduced (median correlation coefficient, 0.72-0.78 for activation time maps after spatio-temporal smoothing). Epicardial foci were identified with a median location error approximate to 16 mm (interquartile range, 9-29 mm). Inverse mapping with meshless method of fundamental solutions was better than with finite/boundary element methods, and the latter were not improved by inclusion of inhomogeneous torso electrical properties. CONCLUSIONS: Inverse potential mapping provides useful information on the origin and spread of epicardial activation. However the spatio-temporal variability of recovered electrograms limit resolution and must constrain the accuracy with which arrhythmia circuits can be identified independently using this approach.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据