4.8 Article

Molecular imprinting coupled with electrochemical analysis for plasma samples classification in acute myocardial infarction diagnostic

期刊

BIOSENSORS & BIOELECTRONICS
卷 99, 期 -, 页码 216-222

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2017.07.026

关键词

Molecularly imprinted polymers; Myoglobin; Poly(ortho-phenylenediamine); Electropolymerization; Cluster assay; Plasma sample classification

向作者/读者索取更多资源

Electroanalysis of myoglobin (Mb) in 10 plasma samples of healthy donors (HDs) and 14 plasma samples of patients with acute myocardial infarction (AMI) was carried out with screen-printed electrodes modified first with multi-walled carbon nanotubes (MWCNT) and then with a molecularly imprinted polymer film (MIP), viz., myoglobin-imprinted electropolymerized poly(o-phenylenediamine). The differential pulse voltammetry (DPV) parameters, such as a maximum amplitude of reduction peak current (A, nA), a reduction peak area (S, nA x V), and a peak potential (P, V), were measured for the MWCNT/MIP-sensors after their incubation with non diluted plasma. The relevance of the multi-parameter electrochemical data for accurate discrimination between HDs and patients with AMI was assessed on the basis of electrochemical threshold values (this requires the reference standard method (RAMP immunoassay)) or alternatively on the basis of the computational cluster assay (this does not require any reference standard method). The multi-parameter electrochemical analysis of biosamples combined with computational cluster assay was found to provide better accuracy in classification of plasma samples to the groups of HDs or AMI patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据