4.5 Article

A generalized method for the segmentation of exudates from pathological retinal fundus images

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.bbe.2017.10.003

关键词

Exudates; Diabetic retinopathy; Segmentation; Retinal fundus Image; Lesion and image based evaluation

向作者/读者索取更多资源

Diabetic retinopathy, an asymptomatic complication of diabetes, is one of the leading causes of blindness in the world. The exudates, abnormal leaked fatty deposits on retina, are one of the most prevalent and earliest clinical signs of diabetic retinopathy. In this paper, a generalized exudates segmentation method to assist ophthalmologists for timely treatment and effective planning in the diagnosis of diabetic retinopathy is developed. The main contribution of the proposed method is the reliable segmentation of exudates using dynamic decision thresholding irrespective of associated heterogeneity, bright and faint edges. The method is robust in the sense that it selects the threshold value dynamically irrespective of the large variations in retinal fundus images from varying databases. Since no performance comparison of state of the art methods is available on common database, therefore, to make a fair comparison of the proposed method, this work has been performed on a diversified database having 1307 retinal fundus images of varying characteristics namely: location, shapes, color and sizes. The database comprises of 649 clinically acquired retinal fundus images from eye hospital and 658 retinal images from publicly available databases such as STARE, MESSIDOR, DIARETDB1 and e-Optha EX. The segmentation results are validated by performing two sets of experiments namely: lesion based evaluation criteria and image based evaluation criteria. Experimental results at lesion level show that the proposed method outperforms other existing methods with a mean sensitivity/specificity/accuracy of 88.85/96.15/93.46 on a composite database of retinal fundus images. The segmentation results for image-based evaluation with a mean sensitivity/specificity/accuracy of 94.62/98.64/96.74 respectively prove the clinical effectiveness of the method. Furthermore, the significant collective performance of these experiments on clinically as well as publicly available standard databases proves the generalization ability and the strong candidature of the proposed method in the real-time diagnosis of diabetic retinopathy. (C) 2017 Nalecz Institute of Biocybernetics and Biomedical Engineering of the Polish Academy of Sciences. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据