4.7 Article

Experimental study on heat transfer enhancement characteristics of tube with cross hollow twisted tape inserts

期刊

APPLIED THERMAL ENGINEERING
卷 131, 期 -, 页码 743-749

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2017.12.029

关键词

Cross hollow twisted tape inserts; Hollow width; Turbulent flow; Heat transfer enhancement

资金

  1. Sub-project of National Key Research and Development Program of China - China [2017YFB0602901-4]

向作者/读者索取更多资源

This study experimentally investigates the heat transfer and friction factor (f) characteristics of a tube fitted with cross hollow twisted tape inserts of hollow widths of 6, 8 and 10 mm under uniform heat flux. Experimental data of a plain tube are compared to the standard correlations for validation. Results show that the Nusselt number (Nu) and f decrease and then increase as the hollow width increases from 6 mm to 10 mm. Nu and f for the 6 mm hollow width increase by 93%-120% and 883%-1042%, respectively, in comparison with those of the plain tube. The performance evaluation criterion (PEC) varies from 0.87 to 0.98 under a Reynolds number of 5600-18,000. Correlations based on the experimental data are established to predict Nu and f under turbulent flow. These parameters match the experimental data well within 3.6% (Nu) and 2.3% (f). (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据