4.8 Article

Passive Picoinjection Enables Controlled Crystallization in a Droplet Microfluidic Device

期刊

SMALL
卷 13, 期 41, 页码 -

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/smll.201702154

关键词

calcium carbonate; crystallization; device fouling; microfluidics; picoinjector

资金

  1. Engineering and Physical Sciences Research Council (EPSRC) [EP/L015005/1, EP/N002423/1]
  2. Engineering and Physical Sciences Research Council [EP/L015005/1] Funding Source: researchfish
  3. EPSRC [EP/N002423/1, EP/K039202/1, EP/L015005/1] Funding Source: UKRI

向作者/读者索取更多资源

Segmented flow microfluidic devices offer an attractive means of studying crystallization processes. However, while they are widely employed for protein crystallization, there are few examples of their use for sparingly soluble compounds due to problems with rapid device fouling and irreproducibility over longer run-times. This article presents a microfluidic device which overcomes these issues, as this is constructed around a novel design of picoinjector that facilitates direct injection into flowing droplets. Exploiting a Venturi junction to reduce the pressure within the droplet, it is shown that passive injection of solution from a side-capillary can be achieved in the absence of an applied electric field. The operation of this device is demonstrated for calcium carbonate, where highly reproducible results are obtained over long run-times at high supersaturations. This compares with conventional devices that use a Y-junction to achieve solution loading, where in-channel precipitation of calcium carbonate occurs even at low supersaturations. This work not only opens the door to the use of microfluidics to study the crystallization of low solubility compounds, but the simple design of a passive picoinjector will find wide utility in areas including multistep reactions and investigation of reaction dynamics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据