4.6 Article

Real-Time External Respiratory Motion Measuring Technique Using an RGB-D Camera and Principal Component Analysis

期刊

SENSORS
卷 17, 期 8, 页码 -

出版社

MDPI AG
DOI: 10.3390/s17081840

关键词

respiratory motion; radiotherapy; RGB-D camera; principal component analysis (PCA)

资金

  1. 'The Cross-Ministry Giga KOREA Project' grant - Korea Government (MSIT) [GK17P0300]
  2. Convergence R&D Development Project of the Small and Medium Administration, Republic of Korea [S2392741]
  3. Institute for Information & Communication Technology Planning & Evaluation (IITP), Republic of Korea [GK17P0300] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. Korea Technology & Information Promotion Agency for SMEs (TIPA) [S2392741] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Accurate tracking and modeling of internal and external respiratory motion in the thoracic and abdominal regions of a human body is a highly discussed topic in external beam radiotherapy treatment. Errors in target/normal tissue delineation and dose calculation and the increment of the healthy tissues being exposed to high radiation doses are some of the unsolicited problems caused due to inaccurate tracking of the respiratory motion. Many related works have been introduced for respiratory motion modeling, but a majority of them highly depend on radiography/fluoroscopy imaging, wearable markers or surgical node implanting techniques. We, in this article, propose a new respiratory motion tracking approach by exploiting the advantages of an RGB-D camera. First, we create a patient-specific respiratory motion model using principal component analysis (PCA) removing the spatial and temporal noise of the input depth data. Then, this model is utilized for real-time external respiratory motion measurement with high accuracy. Additionally, we introduce a marker-based depth frame registration technique to limit the measuring area into an anatomically consistent region that helps to handle the patient movements during the treatment. We achieved a 0.97 correlation comparing to a spirometer and 0.53 mm average error considering a laser line scanning result as the ground truth. As future work, we will use this accurate measurement of external respiratory motion to generate a correlated motion model that describes the movements of internal tumors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据