Real time thermal monitoring of lithium batteries with fiber sensors and thermocouples: A comparative study

期刊

MEASUREMENT
卷 111, 期 -, 页码 260-263

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.measurement.2017.07.049

关键词

Fiber sensors; Thermocouples; Temperature monitoring; Lithium batteries; Abusive conditions

资金

  1. European project Stable Interfaces for Rechargeable Batteries (SIRBATT) [608502]
  2. FEDER through COMPETE Programme
  3. National Funds through FCT - Portuguese Foundation for Science and Technology [UID/CTM/50025/2013]
  4. [BI/UI6642/2016]
  5. [BPD/UI96/7331/2016]

向作者/读者索取更多资源

This work shows a comparative study between the thermocouples and fiber sensors response for the monitoring of temperature variations occurring in three different locations of a lithium battery. The battery is submitted to constant current charge and different discharge rates, under normal and abusive operating conditions. For this specific application, the results show that the fiber Bragg grating sensors have better resolution and a rise time 28.2% lower than the K-type thermocouples, making them a better choice for the real time monitoring of the battery surface temperature as well as a useful tool for failure detection and an optimized management in batteries.