4.6 Article

Temperature influence on nitrogen removal in a hybrid constructed wetland system in Northern Italy

期刊

ECOLOGICAL ENGINEERING
卷 75, 期 -, 页码 291-302

出版社

ELSEVIER
DOI: 10.1016/j.ecoleng.2014.11.027

关键词

Vertical flow (VF); Horizontal flow (HF); Temperature; VF operation mode; Phragmites australis; Canna indica

资金

  1. Progetto AGER [2010-2220]

向作者/读者索取更多资源

The objective of this research was to investigate the efficiency and seasonal performance of a full-scale hybrid constructed wetland system (HCW) in reducing total nitrogen (TN), ammonia nitrogen (NH4-N) and nitrate nitrogen (NO3-N). HCW with a total area of about 130 m(2) and hydraulic load of 2 m(3)/day was composed of three subsurface flow vertical systems (VF), working in parallel and one horizontal (HF) connected in series. The system was loaded daily with synthetic wastewater having an average concentration of TN of 250 mg/L (about 125 mg/L of NH4-N and 125 mg/L of NO3-N). Water samples were collected and analyzed from May to July 2011 and from January 2012 to July 2012. Variations were observed in nutrient removal performance related to temperature. During the whole monitoring period median reduction efficiency (RE) in the HCW was TN 95%, NH4-N 95% and NO3-N 93%, although three sub-periods characterized by different performances have been observed. During the first period (from May to July 2011) the RE was positive for the three nitrogen forms considered, whereas from January to the end of March 2012 the RE was lower, particularly for TN and NO3-N. From April 2012, when the temperature rose above 14.8 degrees C, there was an increase in the performance that reached the 2011 values. Internal production of NO3-N was observed, mainly in the VF systems between January and March 2012. The median removals of mass pollutants per m(2) of HCW per day were TN 3.1 g/m(2)/d, NH4-N 1.5 g/m(2)/d, NO3-N 1.5 g/m(2)/d. Segmented regression analysis identified a breakpoint at 14.2 degrees C for wastewater temperature that caused variations in TN and NO3-N concentration reduction performances. According to this approach the abatement was always positively correlated with temperature, but different regression slopes were obtained below and above the breakpoint. In particular, with lower temperature the abatement of NO3-N and TN increased by 1.7 and 2.0% per degrees C of temperature increase; with temperature higher than 14.2 degrees C the increase in abatement due to increased temperature was sharper, especially for NO3-N . (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据