4.3 Article

Removal of typical antibiotics in the advanced treatment process of productive drinking water

期刊

DESALINATION AND WATER TREATMENT
卷 57, 期 24, 页码 11386-11391

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/19443994.2015.1040848

关键词

Biological activated carbon; Ozonation; Water treatment plant; Antibiotics; Drinking water

资金

  1. National Natural Science Foundation of China [51278285]
  2. Shandong Provincial Natural Science Foundation, China [ZR2010EM019]
  3. National Science and Technology Major Project of China [2012ZX07404-003]

向作者/读者索取更多资源

This study investigated the fate of six artificial antibiotics during treatment process of an industrial-scale drinking water treatment plant in China. The results showed that all the antibiotics can be effectively removed by the advanced treatment process. The average concentrations of the six antibiotics ranged from 1 to 43ng/L in the influent while from non-detected to 6ng/L in the effluent. The antibiotic removal efficiencies were 91% for total antibiotics, 85% for amoxicillin, 92% for tetracycline, 86% for oxytetracycline, and approximately 100% for sulfamethoxazole, sulfamethazine, and erythromycin in the integrated water treatment process. Of all treatment units in the plant, it was found that ozonation and biological activated carbon treatment were the most effective treatment to remove antibiotics.