期刊
IEEE TRANSACTIONS ON POWER DELIVERY
卷 32, 期 4, 页码 1655-1664出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPWRD.2016.2557490
关键词
Dimensional analysis; disc-type winding; flow distribution; OD cooling mode; pressure drop; transformer
资金
- MI Materials
- National Grid
- Scottish Power
- Shell
- TJ | H2b Analytical Services
- UK Power Networks
- Weidmann Electrical Technology
In this paper, a method for predicting pressure drop and flow distribution in disc-type transformer windings in an oil-forced and directed cooling mode is proposed. First, dimensional analyses are conducted to identify the independent dimensionless variables that affect pressure drop over and flow distribution in the winding. Next, parametric sweeps are performed with computational fluid dynamics simulations under isothermal flow conditions. Finally, pressure drop and flow distribution results obtained from the simulations are correlated with the previously identified dimensionless variables to derive correlation equations. These equations have been verified over a range of different isothermal and non-isothermal flow cases and applied to identify the criteria for the occurrence of reverse flow resulting from a combination of pass inlet flow rate and winding geometry. In addition, the method provides an insight into the controlling parameters to determine the minimum oil velocity in horizontal cooling ducts.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐