4.5 Article Proceedings Paper

Effect of steady state and ELMy heat loads on the PFC of DEMO

期刊

FUSION ENGINEERING AND DESIGN
卷 124, 期 -, 页码 478-482

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.fusengdes.2016.12.032

关键词

DEMO; FW blanket module; He coolant; ELMs; Tungsten armor; Material destruction

资金

  1. EURATOM research and training programme [633053]

向作者/读者索取更多资源

It was shown that the edge localized modes (ELM) in steady state DEMO operation can pose a severe tread to the first wall water cooled blanket module due to misalignment Igitkhanov and Bazylev [1]. In this work we estimate the ELM effect on the FW blanket module with helium as a coolant. The characteristics of ELMs in DEMO are derived by using the scaling arguments from experiments, the prediction of peeling ballooning mode theory and by extrapolating results made for ITER. The temperatures of the module materials are calculated for different inlet coolant conditions by using the MEMOS code Bazylev et. al [2]. Calculations show the evolution of the maximum temperatures in the W, EUROFER, Cu alloy and the stainless-steel tube for different level of surface inclination to the magnetic field line. The level of surface inclination to the magnetic field is varied to find when the FW blanket module materials remain within a proper temperature range, limited by crystallization and ductility. (C) 2017 Elsevier B.V. All rights reserved.