期刊
CONSTRUCTION AND BUILDING MATERIALS
卷 80, 期 -, 页码 180-194出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2014.12.097
关键词
Spiral confinement; Grouted splice; Bond stress; Slip
资金
- Universiti Teknologi Malaysia (UTM)
This paper presents the bond behavior of deformed steel reinforcement bars connected by a grouted spiral connection. The bond behavior investigated in this study comprised the mechanism of force transfer, the bond-slip relationship due to the effects of spiral diameter and the comparison of bond stresses between axial and flexural pull-out tests. A total of 36 pull-out specimens and 12 beam specimens were tested until bond failure. The results show that the bond performance between rebars and grout improved significantly due to the confinement provided by the spiral. Reducing the spiral diameter increases the confinement effect and subsequently increases the bond strength. The results also show that the bond strengths obtained from the flexural tests are within the range of 0.74-0.79 times the bond strength of the axial pull-out tests. However, both test results show similar trend of bond behavior with respect to variation in spiral configurations. (C) 2015 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐