4.7 Article

Evaluation of thermochromic elastomeric roofs roof coatings for low-slope roofs

期刊

ENERGY AND BUILDINGS
卷 155, 期 -, 页码 459-466

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2017.09.030

关键词

Thermochromic roof; Cool roof; Sustainable building; Smart roof

向作者/读者索取更多资源

Thermochromic elastomeric roof coatings for low-slope roofs were prepared by incorporating a commercial thermochromic dye (with transition temperature, T-c similar to 32 degrees C) into a white acrylic elastomer matrix. Freshly applied coatings showed an initial temperature-dependent solar reflectance change of 22-25%, with a maximum solar reflectance of 70% in the colorless state (T>T-c). Weathering studies revealed that these thermochromic coatings undergo irreversible photodegradation in as little as 96 h of accelerated aging. Attempts to protect thermochromic dyes with inorganic (nano-ZnO) or organic (Lowilite (R) 20S) UV absorbers were partially successful but need significant improvements to achieve the required lifetime of at least 10 years. Cost calculations in three different geographies showed that even if the durability of these coatings is greatly improved, the energy savings relative to the incumbent static cool roofs are small and do not currently justify the additional cost of thermochromic pigments and UV absorbers. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据