4.6 Article

Domestic Wastewater Depuration Using a Horizontal Subsurface Flow Constructed Wetland and Theoretical Surface Optimization: A Case Study under Dry Mediterranean Climate

期刊

WATER
卷 8, 期 10, 页码 -

出版社

MDPI
DOI: 10.3390/w8100434

关键词

sewage phytodepuration; Mediterranean climate; Phragmites australis; legal requirements; optimal design; abatement efficiency rates

向作者/读者索取更多资源

The wastewater generated by isolated houses without access to public sewers can cause environmental problems, like the contamination of aquifers with nitrates and phosphates, as occurs in southeastern Spain. The effectiveness of a previously built horizontal subsurface flow constructed wetland (HF-CW) was studied over two years as a possible solution. This HF-CW measured 27 m(2); it was planted with Phragmites australis (Cav.) Trin. ex Steud ssp. altissima and the parameters studied were those required by European Union (EU) legislation and adopted by Spain. Average abatement efficiency rates, for the first and the second year of study, were: biochemical oxygen demand over five days (BOD5) (96.4%, 92.0%), chemical oxygen demand (COD) (84.6%, 77.7%), total suspended solids (TSS) (94.8%, 89.9%), total nitrogen (TN) (79.5%, 66.0%), ammonium nitrogen (NH4+-N) (98.8%, 86.6%) and total phosphorous (TP) (83.7%, 82.8%). Average abatement efficiency for nitrate nitrogen (NO3--N) (-1280.5%, -961.1%) and nitrite nitrogen (NO2--N) (-5.8%, -40.0%) were negative because its content in influent wastewater was very low and they appear mainly from influent NH4+-N, as a result of purification processes carried out in the HF-CW bed. The abatement rates make the system suitable to produce discharges into the environment in accordance with Spanish law. It is noteworthy that the HF-CW patch suffered an episode of bed drying during the summer of 2013, whereby the causes were related to system oversizing and high evapotranspiration in the area. As a consequence, the decrease in the abatement of water pollutants during the second year can be attributed to the creation of preferential water flow paths and short circuits through the constructed wetland (CW) bed. As a result of the oversizing of the CW, a theoretical resizing based on BOD5, TSS, TN or TP is proposed. The calculated values for the redesign were: 5.22 m(2) considering DBO5, 0.18 m(2) considering TSS, 10.14 m(2) considering TN and 23.83 m(2) considering TP. Considering the area where the HF-CW was located and in accordance with Spanish law for non-sensitive areas (no TN or TP requirements for wastewater discharge), BOD5 is the most appropriate parameter for design; it is 5.2 times lower than the HF-CW initially built and without risk of bed drying.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据