4.6 Article

Tumor resection at the pelvis using three-dimensional planning and patient-specific instruments: a case series

期刊

WORLD JOURNAL OF SURGICAL ONCOLOGY
卷 14, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/s12957-016-1006-2

关键词

Sarcomas; Pelvis; Three-dimensional (3-D, 3D) planning; 3-D-printed models; Patient-specific instruments (PSI); Patient-specific guides (PSG); Patient-specific templates (PST); Resection margins

向作者/读者索取更多资源

Background: Sarcomas are associated with a relatively high local recurrence rate of around 30 % in the pelvis. Inadequate surgical margins are the most important reason. However, obtaining adequate margins is particularly difficult in this anatomically demanding region. Recently, three-dimensional (3-D) planning, printed models, and patient-specific instruments (PSI) with cutting blocks have been introduced to improve the precision during surgical tumor resection. This case series illustrates these modern 3-D tools in pelvic tumor surgery. Methods: The first consecutive patients with 3-D-planned tumor resection around the pelvis were included in this retrospective study at a University Hospital in 2015. Detailed information about the clinical presentation, imaging techniques, preoperative planning, intraoperative surgical procedures, and postoperative evaluation is provided for each case. The primary outcome was tumor-free resection margins as assessed by a postoperative computed tomography (CT) scan of the specimen. The secondary outcomes were precision of preoperative planning and complications. Results: Four patients with pelvic sarcomas were included in this study. The mean follow-up was 7.8 (range, 6.0-9.0) months. The combined use of preoperative planning with 3-D techniques, 3-D-printed models, and PSI for osteotomies led to higher precision (maximal (max) error of 0.4 centimeters (cm)) than conventional 3-D planning and freehand osteotomies (max error of 2.8 cm). Tumor-free margins were obtained where measurable (n = 3; margins were not assessable in a patient with curettage). Two insufficiency fractures were noted postoperatively. Conclusions: Three-dimensional planning as well as the intraoperative use of 3-D-printed models and PSI are valuable for complex sarcoma resection at the pelvis. Three-dimensionally printed models of the patient anatomy may help visualization and precision. PSI with cutting blocks help perform very precise osteotomies for adequate resection margins.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据