4.8 Article

A modeling approach to estimate the solar disinfection of viral indicator organisms in waste stabilization ponds and surface waters

期刊

WATER RESEARCH
卷 88, 期 -, 页码 912-922

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2015.11.022

关键词

APEX; Solar disinfection model; Virus inactivation; Waste stabilization pond

资金

  1. EPFL
  2. Swiss National Science Foundation [118077, 131918]
  3. Universita di Torino - EU Accelerating Grants [TO_Call2_2012_0047]

向作者/读者索取更多资源

Sunlight is known to be a pertinent factor governing the infectivity of waterborne viruses in the environment. Sunlight inactivates viruses via endogenous inactivation (promoted by absorption of solar light in the UVB range by the virus) and exogenous processes (promoted by adsorption of sunlight by external chromophores, which subsequently generate inactivating reactive species). The extent of inactivation is still difficult to predict, as it depends on multiple parameters including virus characteristics, solution composition, season and geographical location. In this work, we adapted a model typically used to estimate the photodegradation of organic pollutants, APEX, to explore the fate of two commonly used surrogates of human viruses (coliphages MS2 and phi X174) in waste stabilization pond and natural surface water. Based on experimental data obtained in previous work, we modeled virus inactivation as a function of water depth and composition, as well as season and latitude, and we apportioned the contributions of the different inactivation processes to total inactivation. Model results showed that phi X174 is inactivated more readily than MS2, except at latitudes >60 degrees. phi X174 inactivation varies greatly with both season (20-fold) and latitude (10-fold between 0 and 60 degrees), and is dominated by endogenous inactivation under all solution conditions considered. In contrast, exogenous processes contribute significantly to MS2 inactivation. Because exogenous inactivation can be promoted by longer wavelengths, which are less affected by changes in season and latitude, MS2 exhibits smaller fluctuations in inactivation throughout the year (10-fold) and across the globe (3-fold between 0 and 60 degrees) compared to phi X174. While a full model validation is currently not possible due to the lack of sufficient field data, our estimated inactivation rates corresponded well to those reported in field studies. Overall, this study constitutes a step toward estimating microbial water quality as a function of spatio-temporal information and easy-to-determine solution parameters. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据