期刊
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY
卷 51, 期 -, 页码 414-423出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.tust.2015.09.007
关键词
Tunnel fire; Heat release rate; Cross section; Ventilation
资金
- SP Tunnel and Underground Safety Center
- Swedish Research Council (FORMAS)
Model scale fire tests were performed in tunnels with varying tunnel widths and heights in order to study the effect of tunnel cross-section and ventilation velocity on the heat release rate (HRR) for both liquid pool fires and solid fuel fires. The results showed that for well ventilated heptane pool fires, the tunnel width nearly has no influence on the HRR whilst a lower tunnel height clearly increases the HRR. For well ventilated solid fuel fires, the HRR increases by approximately 25% relative to a free burn test but the HRR is not sensitive to either tunnel width, tunnel height or ventilation velocity. For solid fuel fires that were not well ventilated, the HRRs could be less than those in free burn laboratory tests. In the case of ventilation controlled fires the HRRs approximately lie at the same level as for cases with natural ventilation. (C) 2015 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据