4.7 Article

Analytical approach to determining human biogenic amines and their metabolites using eVol microextraction in packed syringe coupled to liquid chromatography mass spectrometry method with hydrophilic interaction chromatography column

期刊

TALANTA
卷 150, 期 -, 页码 331-339

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2015.12.056

关键词

Microextraction in packed syringe (MEPS); HILIC chromatography; Biogenic amines; Human plasma samples; Human urine samples

资金

  1. National Science Centre, Poland [2011/03/B/NZ7/02333]

向作者/读者索取更多资源

Analysis of biogenic amines (BAs) in different human samples provides insight into the mechanisms of various biological processes, including pathological conditions, and thus may be very important in diagnosing and monitoring several neurological disorders and cancerous tumors. In this work, we developed a simple and fast procedure using a digitally controlled microextraction in packed syringe (MEPS) coupled to liquid chromatography mass spectrometry (LC-MS) method for simultaneous determination of biogenic amines, their precursors and metabolites in human plasma and urine samples. The separation of 12 low molecular weight and hydrophilic molecules with a wide range of polarities was achieved with hydrophilic interaction chromatography (HILIC) column without derivatization step in 12 min. MEPS was implemented using the APS sorbent in semi-automated analytical syringe (eVol (R)) and small volume of urine and plasma samples, 50 mu L and 100 mu L, respectively. We evaluated important parameters influencing MEPS efficiency, including stationary phase selection, sample pH and volume, number of extraction cycles, and washing and elution volumes. In optimized MEPS conditions, the analytes were eluted by 3 x 50 mu L of methanol with 0.1% formic acid. The chromatographic separation of analytes was performed on XBridge Amide (TM) BEH analytical column (3.0 mm x 100 mm, 3.5 mu m) using gradient elution with mobile phase consisting of phase A: 10 mM ammonium formate buffer in water pH 3.0 and phase B: 10 mM ammonium formate buffer in acetonitrile pH 3.0. The LC-HILIC-MS method was validated and, in optimum conditions, presented good linearity in concentration range within 102000 ng/mL for all the analytes with a determination coefficient (r(2)) higher than 0.999 for plasma and urine samples. Method recovery ranged within 87.6-404.3% for plasma samples and 84.2-98.6% for urine samples. The developed method utilizing polar APS sorbent along with polar HILIC column was applied for simultaneous bioanalysis of trace amounts of polar endogenous biogenic amines in real human urine and plasma samples. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据