4.6 Article

Development and validation of a sensor- and expert model-based training system for laparoscopic surgery: the iSurgeon

期刊

出版社

SPRINGER
DOI: 10.1007/s00464-016-5213-2

关键词

Minimally invasive surgery; Assessment; Education; Laparoscopic suturing and knot tying; Computer-assisted surgery; Kinect

类别

资金

  1. German Research Foundation [SFB/Transregio 125]
  2. European Social Fund of the State Baden Wuerttemberg

向作者/读者索取更多资源

Training and assessment outside of the operating room is crucial for minimally invasive surgery due to steep learning curves. Thus, we have developed and validated the sensor- and expert model-based laparoscopic training system, the iSurgeon. Participants of different experience levels (novice, intermediate, expert) performed four standardized laparoscopic knots. Instruments and surgeons' joint motions were tracked with an NDI Polaris camera and Microsoft Kinect v1. With frame-by-frame image analysis, the key steps of suturing and knot tying were identified and registered with motion data. Construct validity, concurrent validity, and test-retest reliability were analyzed. The Objective Structured Assessment of Technical Skills (OSATS) was used as the gold standard for concurrent validity. The system showed construct validity by discrimination between experience levels by parameters such as time (novice = 442.9 +/- 238.5 s; intermediate = 190.1 +/- 50.3 s; expert = 115.1 +/- 29.1 s; p < 0.001), total path length (novice = 18,817 +/- 10318 mm; intermediate = 9995 +/- 3286 mm; expert = 7265 +/- 2232 mm; p < 0.001), average speed (novice = 42.9 +/- 8.3 mm/s; intermediate = 52.7 +/- 11.2 mm/s; expert = 63.6 +/- 12.9 mm/s; p < 0.001), angular path (novice = 20,573 +/- 12,611A degrees; intermediate = 8652 +/- 2692A degrees; expert = 5654 +/- 1746A degrees; p < 0.001), number of movements (novice = 2197 +/- 1405; intermediate = 987 +/- 367; expert = 743 +/- 238; p < 0.001), number of movements per second (novice = 5.0 +/- 1.4; intermediate = 5.2 +/- 1.5; expert = 6.6 +/- 1.6; p = 0.025), and joint angle range (for different axes and joints all p < 0.001). Concurrent validity of OSATS and iSurgeon parameters was established. Test-retest reliability was given for 7 out of 8 parameters. The key steps wrapping the thread around the instrument and needle positioning were most difficult to learn. Validity and reliability of the self-developed sensor-and expert model-based laparoscopic training system iSurgeon were established. Using multiple parameters proved more reliable than single metric parameters. Wrapping of the needle around the thread and needle positioning were identified as difficult key steps for laparoscopic suturing and knot tying. The iSurgeon could generate automated real-time feedback based on expert models which may result in shorter learning curves for laparoscopic tasks. Our next steps will be the implementation and evaluation of full procedural training in an experimental model.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据