4.7 Article

Tomosynthesis in the Diagnostic Setting: Changing Rates of BI-RADS Final Assessment over Time

期刊

RADIOLOGY
卷 281, 期 1, 页码 54-61

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2016151999

关键词

-

资金

  1. Hologic
  2. Siemens Medical
  3. Fuji
  4. Q View Medical
  5. Siemens

向作者/读者索取更多资源

Purpose: To evaluate the effect of tomosynthesis in diagnostic mammography on the Breast Imaging Reporting and Data System (BI-RADS) final assessment categories over time. Materials and Methods: This retrospective study was approved by the institutional review board. The authors reviewed all diagnostic mammograms obtained during a 12-month interval before (two-dimensional [2D] mammography [June 2, 2010, to June 1, 2011]) and for 3 consecutive years after (tomosynthesis year 1 [2012], tomosynthesis year 2 [2013], and tomosynthesis year 3 [2014]) the implementation of tomosynthesis. The requirement to obtain informed consent was waived. The rates of BI-RADS final assessment categories 1-5 were compared between the 2D and tomosynthesis groups. The positive predictive values after biopsy (PPV3) for BI-RADS category 4 and 5 cases were compared. The mammographic features (masses, architectural distortions, calcifications, focal asymmetries) of lesions categorized as probably benign (BI-RADS category 3) and those for which biopsy was recommended (BI-RADS category 4 or 5) were reviewed. The chi(2) test was used to compare the rates of BI-RADS final assessment categories 1-5 between the two groups, and multivariate logistic regression analysis was performed to compare all diagnostic studies categorized as BI-RADS 3-5. Results: There was an increase in the percentage of cases reported as negative or benign (BI-RADS category 1 or 2) with tomosynthesis (58.7% with 2D mammography vs 75.8% with tomosynthesis at year 3, P < .0001). A reduction in the percentage of probably benign (BI-RADS category 3) final assessments also occurred (33.3% with 2D mammography vs 16.4% with tomosynthesis at year 3, P < .0001). Although the rates of BI-RADS 4 or 5 assessments did not change significantly with tomosynthesis (8.0% with 2D mammography vs 7.8% with tomosynthesis at year 3, P =.2), there was a significant increase in the PPV3 (29.6% vs 50%, respectively; P < .0001). These trends increased during the 3 years of tomosynthesis use. Conclusion: Tomosynthesis in the diagnostic setting resulted in progressive shifts in the BI-RADS final assessment categories over time, with a significant increase in the proportion of studies classified as normal, a continued decrease in the rate of studies categorized as probably benign, and improved diagnostic confidence in biopsy recommendations. (C) RSNA, 2016

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据