4.3 Review

Inverted Internal Limiting Membrane Flap VS. ILM Peeling for<400μm Macular Hole: a meta-analysis and systematic review

期刊

OPHTHALMIC RESEARCH
卷 -, 期 -, 页码 -

出版社

KARGER
DOI: 10.1159/000534873

关键词

ILM peeling; inverted ILM flap; macular hole; M & uuml;ller cells

向作者/读者索取更多资源

This study compared the outcomes of vitrectomy combined with the inverted internal limiting membrane (ILM) flap and ILM peeling for small and medium-sized macular holes (MHs). The results showed no significant difference in MH closure rate, visual acuity, or the integrity of the external limiting membrane (ELM) and ellipsoid zone (EZ) between the two techniques. Therefore, the use of ILM flap for surgical repair of small MHs seems to be as effective as the traditional technique.
Purpose: The inverted internal limiting membrane (ILM) flap technique was initially developed for the closure of large macular holes (MH). However, its efficacy in treating small holes has been a matter of debate. This study aimed to compare the anatomical and visual outcomes of vitrectomy (PPV) combined with the inverted ILM flap and ILM peeling in cases of small and medium-sized MHs. Methods: A meta-analysis was conducted by searching the relevant literature in databases, including PubMed, Web of Science, Embase, and Cochrane Library. The search included articles published from the inception of the databases up until January 2023. The inclusion criteria limited the studies to only experimental based research. The heterogeneity, publication bias, and sensitivity analysis were performed to ensure the statistical power and reliability of the analysis. Results: Five studies, including two RCTs and three non-randomized concurrent control trials (n-RCTs), comprising a total of 269 eyes, were analyzed. The results showed no significant difference in the MH closure rate between the two group (odds ratio (OR) = 0.29, 95% confidence interval (CI): 0.04-1.96, P = 0.33). Furthermore, there were no significant differences observed in visual acuity, external limiting membrane (ELM) and ellipsoid zone (EZ) integrity at 3 months (ELM OR = 0.88, EZ OR = 0.85) or 12 months (ELM OR = 0.96, EZ OR = 1.39) post-operation between the two groups. Conclusion: The surgical repair of MHs smaller than 400 mu m with ILM flap seem to be similar in VA improvement and anatomical recovery compared to the traditional technique.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据