4.7 Article

Toxic cadmium(II) monitoring and removal from aqueous solution using ligand-based facial composite adsorbent

期刊

JOURNAL OF MOLECULAR LIQUIDS
卷 389, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.molliq.2023.122854

关键词

Cadmium(II); Facial composite adsorbent; Monitoring and removal; Selectivity; Sensitivity

向作者/读者索取更多资源

Developing an eco-friendly composite adsorbent and process for detection and removal of Cd(II) from wastewater is urgently needed. The facial composite adsorbent (FCA) containing 2,2'-Biquinoline-4,4'-dicarboxylic acid (BIDA) ligand showed excellent adsorption capacity and colorimetric detection ability for Cd(II) ions. FCA demonstrated high reusability and potential for remediation of Cd(II) polluted water.
Developing an eco-friendly composite adsorbent via an eco-friendly process for detection and removing Cd(II) from wastewater is urgently necessary due to the critical hazards of Cd(II) to public health and environmental safety. The chemical ligand of 2,2 & PRIME;-Biquinoline-4,4 & PRIME;-dicarboxylic acid (BIDA) was embedded directly on the mesoporous silica for the fabrication of facial composite adsorbent (FCA) for toxic cadmium (Cd(II)) ion detection and removal from wastewater solutions. The FCA nanostructures were characterized by SEM, TEM, and N2 adsorption/desorption analyzer systematically. The physicochemical properties of FCA, as well as the primary influencing factors and mechanism of Cd(II) detection and adsorption processes, were also investigated. More interestingly, a colorimetric method based on color enhancement upon adding Cd(II) was developed by the FCA to detect low concentrations of Cd(II) ions. The solution pH played a key factor in color formation and neutral pH of 7.0 was selected based on the optimum color formation. The limit of detection was 0.39 & mu;g/L. The preeminent adsorption capacity of FCA toward Cd(II) was (159.21 mg/g) which was mainly ascribed to the complexation of Cd(II) with the functional groups of BIDA coating FCA. The adsorption isotherms and kinetics data preferably conformed to the Langmuir isotherms model with monolayer coverage. The detection and adsorption of Cd(II) were not affected by other cations at the optimum experimental conditions. The FCA exhibited high reusability based on the elution and regeneration performances. The elution was carried out using 0.20 M HCl and then the FCA was ready to use after washing with water without loss in its functionality. The successful removal and detection of Cd(II) water samples demonstrates the great potential of the proposed FCA to remediate Cd(II) polluted water to safeguard water quality.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据