A new method for investigating bioequivalence of inhaled formulations: A pilot study on salbutamol

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/jpps.2023.11466

关键词

salbutamol; bioequivalence; inhaled formulations; exhaled breath condensate; pharmacokinetics

向作者/读者索取更多资源

This study tested the practical applicability of a previously proposed hypothesis on the bioequivalence of inhaled salbutamol formulations using two different types of pressurized metered dose inhalers (MDI-1 and MDI-2). The results showed that there was no significant bioequivalence between the two formulations based on the comparison of salbutamol concentration profiles in exhaled breath condensate (EBC) samples and the determination of aerodynamic particle size distribution.
Purpose: An efficient, cost-effective and non-invasive test is required to overcome the challenges faced in the process of bioequivalence (BE) studies of various orally inhaled drug formulations. Two different types of pressurized meter dose inhalers (MDI-1 and MDI-2) were used in this study to test the practical applicability of a previously proposed hypothesis on the BE of inhaled salbutamol formulations.Methods: Salbutamol concentration profiles of the exhaled breath condensate (EBC) samples collected from volunteers receiving two inhaled formulations were compared employing BE criteria. In addition, the aerodynamic particle size distribution of the inhalers was determined by employing next generation impactor. Salbutamol concentrations in the samples were determined using liquid and gas chromatographic methods.Results: The MDI-1 inhaler induced slightly higher EBC concentrations of salbutamol when compared with MDI-2. The geometric MDI-2/MDI-1 mean ratios (confidence intervals) were 0.937 (0.721-1.22) for maximum concentration and 0.841 (0.592-1.20) for area under the EBC-time profile, indicating a lack of BE between the two formulations. In agreement with the in vivo data, the in vitro data indicated that the fine particle dose (FPD) of MDI-1 was slightly higher than that for the MDI-2 formulation. However, the FPD differences between the two formulations were not statistically significant.Conclusion: EBC data of the present work may be considered as a reliable source for assessment of the BE studies of orally inhaled drug formulations. However, more detailed investigations employing larger sample sizes and more formulations are required to provide more evidence for the proposed method of BE assay.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据