Monocular Vision-Based Multiparameter Dynamic Calibration Method Used for the Low-Frequency Linear and Angular Vibration Sensors

期刊

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
卷 70, 期 5, 页码 5365-5374

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIE.2022.3186310

关键词

Calibration; Vibrations; Sensors; Sensitivity; Sensor systems; Vibration measurement; Uncertainty; Linear and angular vibration sensors; low-frequency vibration; line segment detector (LSD) method; monocular vision (MV); multiparameter dynamic calibration

向作者/读者索取更多资源

This article investigates a new monocular vision-based multiparameter calibration method that determines the sensitivities of low-frequency linear and angular vibration sensors in a broad range. The method improves the perfection and unification of linear and angular vibration calibration and achieves satisfactory accuracy with an efficient, flexible, and low-cost system in the low-frequency range.
In this article, the low-frequency linear and angular vibration sensors have been gradually used in many applications of vibration monitoring because they can measure dynamic displacement and angle. These sensors must be calibrated before they are used and after they have been used for a period to ensure their measurement accuracy. Currently, the laser interferometry (LI) and sensor-based comparison method are commonly used to calibrate their sensitivities. However, the former suffers inevitably drawbacks in low-frequency range, while the latter usually has only a limited range, these undoubtedly limit their wide application. In this article, a new monocular vision-based multiparameter calibration method is investigated, which can determine the sensitivities of these sensors in a broad low-frequency range. The monocular vision method with improved line segment detector is applied to measure the linear and angular vibration excitations by extracting the motion feature edges with subpixel accuracy. This investigated method strongly promotes the perfection and unification of linear and angular vibration calibration. Many comparison experiments with the LI, the Earth's graviation method, and the circular grating-based method confirm that the investigated method gets the satisfactory accuracies in the linear and angular vibration calibration with an efficient, flexible, and low-cost system in the low-frequency range.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据