4.8 Article

Sizing and Discovery of Nanosized Polyoxometalate Clusters by Mass Spectrometry

期刊

JOURNAL OF THE AMERICAN CHEMICAL SOCIETY
卷 138, 期 11, 页码 3824-3830

出版社

AMER CHEMICAL SOC
DOI: 10.1021/jacs.6b00070

关键词

-

资金

  1. EPSRC [EP/L023652/1, EP/I033459/1, EP/J015156/1, EP/K023004/1]
  2. EC [318671 MICREAGENTS]
  3. Royal Society/Wolfson Foundation
  4. ERC [670467 SMART-POM]
  5. EPSRC
  6. University of Glasgow
  7. BBSRC [BB/L015048/1, BB/L002655/1] Funding Source: UKRI
  8. EPSRC [EP/L023652/1, EP/H024107/1, EP/I033459/1, EP/C542819/1, EP/J015156/1, EP/K023004/1] Funding Source: UKRI
  9. Biotechnology and Biological Sciences Research Council [BB/L002655/1, BB/L015048/1] Funding Source: researchfish
  10. Engineering and Physical Sciences Research Council [EP/L023652/1, EP/K023004/1, EP/H024107/1, EP/I033459/1, EP/J015156/1, 1134502, EP/C542819/1, 1164940] Funding Source: researchfish

向作者/读者索取更多资源

Ion mobility-mass spectrometry (IM-MS) is a powerful technique for structural characterization, e.g., sizing and conformation, particularly when combined with quantitative modeling and comparison to theoretical values. Traveling wave IM-MS (TW-IM-MS) has recently become commercially available to nonspecialist groups and has been exploited in the structural study of large biomolecules, however reliable calibrants for large anions have not been available. Polyoxometalate (POM) species-nanoscale inorganic anions share many of the facets of large biomolecules, however, the full potential of IM-MS in-their study has yet to be realized due to a lack of suitable calibration data or validated theoretical models. Herein we address these limitations by reporting DT-IM (drift tube) data for a set of POM clusters {M-12} Keggin 1, {M-18} Dawson 2, and two {M-7}. Anderson derivatives 3 and 4 which demonstrate their use as a TW-IM-MS calibrant set to facilitate characterization of very large (ca. 1-4 nm) anionic species. The data was also used to assess the validity of standard techniques to model the collision cross sections of large inorganic anions using the nanoscale family of compounds based upon the {Se2W29} unit including the trimer, {Se8W86O299} A, tetramer, {Se8W116O408} B, and hexamer {Se12W174O612}, including their relative sizing in solution. Furthermore, using this data set, we demonstrated how IM-MS can be used to conveniently characterize and identify the synthesis of two new, i.e., previously unreported POM species, {P8W116}, unknown D, and {Te8W116}, unknown E, which are not amenable to analysis by other means with the approximate formulation of [H34W118X8M2O416](44-), where X = P and M = Co for D and X = Te and M = Mn for E. This work establishes a new type of inorganic calibrant for IM-MS allowing sizing, structural analysis, and discovery of molecular nanostructures directly from solution.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据