4.7 Article

Assessment of the Accuracy of Two Different Dynamic Navigation System Registration Methods for Dental Implant Placement in the Posterior Area: An In Vitro Study

期刊

JOURNAL OF PERSONALIZED MEDICINE
卷 13, 期 1, 页码 -

出版社

MDPI
DOI: 10.3390/jpm13010139

关键词

dynamic navigation system; U-tube registration; cusp registration; dental implant placement

向作者/读者索取更多资源

This study compared the U-tube and cusp dynamic navigation system registration methods for dental implant placement and assessed the impact of missing teeth location on these registrations. The results showed that both methods had acceptable accuracy with no significant difference. However, the U-tube method showed significant difference when assessing the location of missing teeth, while cusp registration was unaffected. Therefore, the cusp dynamic navigation system registration technique is not only accurate but also overcomes the limitations of the U-tube approach and deserves further clinical research.
Purpose: To compare the U-tube and cusp dynamic navigation system registration methods in the use of dental implant placement, and to assess the influence of the location of missing teeth on these registrations. Methods: 32 resin mandible models and 64 implants were utilized, with implants being placed using one of the two registration methods selected at random. Accuracy was measured through the superimposition of the final and planned implant positions. Angular deviation, 3D entry deviation, and 3D apex deviation were analyzed. Results: The overall mean 3D deviation was 1.089 +/- 0.515 mm at the entry point and 1.174 +/- 0.531 mm at the apex point, and mean angular deviation was 1.970 +/- 1.042 degrees. No significant difference (p > 0.05) was observed when comparing these two registration methods. However, the U-tube method showed significant difference when assessing the location of missing teeth (without distal-extension absence and distal-extension absence), whereas cusp registration was unaffected. Conclusions: Both the U-tube and cusp dynamic navigation system registration methods are accurate when implemented in vitro. Besides, the cusp registration technique can also overcome several of the limitations of the U-tube approach and the accuracy of it was not influenced by the location of the missing teeth, highlighting it as a method worthy of further clinical research.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据