4.5 Article

The effect of bone defect size on the 3D accuracy of alveolar bone augmentation performed with additively manufactured patient-specific titanium mesh

期刊

BMC ORAL HEALTH
卷 22, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12903-022-02557-9

关键词

Alveolar bone defects; Additively manufactured patient-specific titanium mesh; Bone augmentation; Digital registration; CAD/CAM

资金

  1. National Natural Science Foundation of China [11872135, 12072055, 12172034, U20A20390]
  2. Natural Science Foundation of Beijing [L212063]
  3. Fundamental Research Funds for the Central Universities

向作者/读者索取更多资源

The size of the bone defect does not have a significant effect on the 3D accuracy of alveolar bone augmentation performed with additively manufactured patient-specific titanium mesh. However, larger bone defects may increase surgical difficulty.
Objective: Additively manufactured (3D-printed) titanium meshes have been adopted in the dental field as nonresorbable membranes for guided bone regeneration (GBR) surgery. However, according to previous studies, inaccuracies between planned and created bone volume and contour are common, and many reasons have been speculated to affect its accuracy. The size of the alveolar bone defect can significantly increase patient-specific titanium mesh design and surgical difficulty. Therefore, this study aimed to analyze and investigate the effect of bone defect size on the 3D accuracy of alveolar bone augmentation performed with additively manufactured patient-specific titanium meshes. Methods: Twenty 3D-printed patient-specific titanium mesh GBR surgery cases were enrolled, in which 10 cases were minor bone defect/augmentation (the planned bone augmentation surface area is less than or equal to 150 mm(2) or one tooth missing or two adjacent front-teeth/premolars missing) and another 10 cases were significant bone defect/augmentation (the planned bone augmentation surface area is greater than 150 mm(2) or missing adjacent teeth are more than two (i.e. >= three teeth) or missing adjacent molars are >= two teeth). 3D digital reconstruction/superposition technology was employed to investigate the bone augmentation accuracy of 3D-printed patient specific titanium meshes. Results: There was no significant difference in the 3D deviation distance of bone augmentation between the minor bone defect/augmentation group and the major one. The contour lines of planned-CAD models in two groups were basically consistent with the contour lines after GBR surgery, and both covered the preoperative contour lines. Moreover, the exposure rate of titanium mesh in the minor bone defect/augmentation group was slightly lower than the major one. Conclusion: It can be concluded that the size of the bone defect has no significant effect on the 3D accuracy of alveolar bone augmentation performed with the additively manufactured patient-specific titanium mesh.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据