4.7 Article

Influence of nucleation on cavitation inception in tip leakage flows

期刊

PHYSICS OF FLUIDS
卷 35, 期 1, 页码 -

出版社

AIP Publishing
DOI: 10.1063/5.0132034

关键词

-

向作者/读者索取更多资源

Cavitation in tip leakage flow was experimentally investigated in a cavitation tunnel using a stationary hydrofoil analogy. Different tip clearances and hydrofoil incidences were tested, while keeping the chord-based Reynolds number fixed. The influence of nucleation on both cavitation inception and development was evaluated using two populations of freestream nuclei. Cavitation was characterized using high-speed imaging and acoustic measurements, and the worst cavitation performance was observed at an intermediate gap height for the strong water case. The optimization of gap height depends on the expected nuclei population during operation.
Cavitation in a tip leakage flow is experimentally investigated in a cavitation tunnel using a stationary hydrofoil analogy. The experiments were performed for different tip clearances (tau = gap height=maximum profile thickness) and hydrofoil incidences (alpha). The chord-based Reynolds number remained fixed at Re = 3 x 10(6). The influence of nucleation on both inception and developed cavitation is evaluated by performing tests with two populations of freestream nuclei: a low concentration with strong critical tensions for activation and a high concentration with weak critical tensions. These populations represent the extremes that would be expected in practical tip leakage flows. Cavitation was characterized using high-speed imaging and acoustic measurements. Following a survey of developed cavitation topology for a range s and a values, alpha = 6 degrees was selected for further investigation of cavitation inception as it demonstrated a rich variety of physical processes. From the acoustic measurements, the worst performance in terms of cavitation inception was observed at an intermediate gap height of around tau = 0.6-0.8 for the strong water case. Broadly, cavitation and inception is intermittent when nuclei are sparse, becoming continuous as additional nuclei are introduced. While a continuous cavity in the seeded flow resulted in a higher baseline acoustic signature, sparse populations allow the leakage vortex to sustain tension, which can result in extremely loud incipient events. Optimization of gap height will, therefore, depend on the expected nuclei population during operation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据