4.6 Article Proceedings Paper

Energy reduction for commercial freezer by force convection cooling of heatsink

期刊

ENERGY REPORTS
卷 8, 期 -, 页码 394-399

出版社

ELSEVIER
DOI: 10.1016/j.egyr.2022.05.169

关键词

Commercial freezer; Energy reduction; Convection heat transfer; Natural convection mechanism; Force convection mechanism

资金

  1. Chiang Mai University Thailand

向作者/读者索取更多资源

This study compares the heat transfer of natural convection and forced convection in the heatsink of a commercial freezer, and finds that forced convection has higher heat transfer and lower energy consumption. At an internal heat load of 6 kg, forced convection reduces energy consumption by 17.5%, 17.7%, and 20.5% compared to natural convection at cooling air velocities of 1, 2, and 3 m/s.
Commercial freezers are commonly used the outer wall as a heatsink. This heatsink needs surrounded ambient air for cooling, which is the natural convection mechanism. However, in theory the force convection provides more heat transfer than the natural convection. Therefore, energy consumption of the force convection is generally less than the natural convection. This study aims at testing and comparing the heat transfer between the natural convection and force convection of the heatsink of the commercial freezer. Moreover, this study investigated the potential of energy reduction of the freezer by using the natural convection and the force convection of the heatsink. In this study, the unmodified commercial freezer installed with the wind tunnel over the heatsink of the freezer was made. The necessary parameters such as heatsink surface temperature, cooling air temperature, ambient air temperature, velocity of cooling air, and power consumption of the freezer were collected. The testing conditions were varied the internal heat load of the freezer by using water as 0, 3, and 6 kg, and varied the cooling air velocity as 0, 1, 2, and 3 m/s. The results showed that the convection mechanism was significantly affected by energy consumption. Furthermore, it was clearly found that the heat transfer for the force convection was higher than the natural convection. Moreover, the use of force convection resulted in a lower energy consumption. In particular at the internal heat load of 6 kg, the energy consumption of the force convection decreased by 17.5%, 17.7%, and 20.5% as compared to the natural convection at the cooling air velocity of 1, 2, and 3 m/s, respectively. Based on the results obtained it can be concluded that the force convection for the freezer heatsink can be used to reduce energy consumption, which could be efficiently applied in the future works. (C) 2022 The Author(s). Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据