4.5 Article

Direct communication between osteocytes and acid-etched titanium implants with a sub-micron topography

出版社

SPRINGER
DOI: 10.1007/s10856-016-5779-1

关键词

-

资金

  1. Swedish Research Council [K2015-52X-09495-28-4]
  2. BIOMATCELL VINN Excellence Centre of Biomaterials and Cell Therapy
  3. Region Vastra Gotaland
  4. ALF/LUA Research Grant Optimization of osseointegration for treatment of transfemoral amputees [ALFGBG-448851]
  5. IngaBritt and Arne Lundberg Foundation
  6. Adlerbertska Foundation
  7. Vilhelm and Martina Lundgren Foundation
  8. Dr. Felix Neubergh Foundation
  9. Promobilia and Hjalmar Svensson Foundation
  10. Swedish Foundation for Strategic Research (SSF) [ICA 10-0074]
  11. Swedish Government Strategic Funding of Materials Science Area of Advance

向作者/读者索取更多资源

The osteocyte network, through the numerous dendritic processes of osteocytes, is responsible for sensing mechanical loading and orchestrates adaptive bone remodelling by communicating with both the osteoclasts and the osteoblasts. The osteocyte network in the vicinity of implant surfaces provides insight into the bone healing process around metallic implants. Here, we investigate whether osteocytes are able to make an intimate contact with topologically modified, but micrometre smooth (S-a < 0.5 mu m) implant surfaces, and if sub-micron topography alters the composition of the interfacial tissue. Screw shaped, commercially pure (cp-Ti) titanium implants with (i) machined (Sa = similar to 0.2 mu m), and (ii) two-step acid-etched (HF/HNO3 and H2SO4/HCl; S-a = similar to 0.5 mu m) surfaces were inserted in Sprague Dawley rat tibia and followed for 28 days. Both surfaces showed similar bone area, while the bone-implant contact was 73% higher for the acid-etched surface. By resin cast etching, osteocytes were observed to maintain a direct intimate contact with the acid-etched surface. Although well mineralised, the interfacial tissue showed lower Ca/P and apatite-to-collagen ratios at the acid-etched surface, while mineral crystallinity and the carbonate-to-phosphate ratios were comparable for both implant surfaces. The interfacial tissue composition may therefore vary with changes in implant surface topography, independently of the amount of bone formed. Implant surfaces that influence bone to have higher amounts of organic matrix without affecting the crystallinity or the carbonate content of the mineral phase presumably result in a more resilient interfacial tissue, better able to resist crack development during functional loading than densely mineralised bone.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据