4.6 Article

Moir? artifacts reduction in Talbot-Lau X-ray phase contrast imaging using a three-step iterative approach

期刊

OPTICS EXPRESS
卷 30, 期 20, 页码 35096-35111

出版社

Optica Publishing Group
DOI: 10.1364/OE.466277

关键词

-

类别

资金

  1. Zhejiang Provincial Ten Thousand Plan for Young Top Talents [2020R52001]
  2. Zhejiang Lab [2020MC0AE01]
  3. Key Research and Development Program of Zhejiang Province [2020C01116]
  4. Major Program of the Natural Science Foundation of Zhejiang Province [LD21F050002]
  5. National Natural Science Foundation of China [61735017, 61827825, 62125504]

向作者/读者索取更多资源

Talbot-Lau X-ray phase contrast imaging is a promising technique that provides absorption, differential phase contrast, and dark-field images simultaneously. This work theoretically derives and systematically summarizes the effects of stepping errors and dose fluctuations on the images. A novel three-step iterative method is designed for image reconstruction to reduce moire artifacts.
Talbot-Lau X-ray phase contrast imaging is a promising technique in biological imaging since it can provide absorption, differential phase contrast, and dark-field images simultaneously. However, high accuracy motorized translation stages and high stability of the imaging system are needed to avoid moire artifacts in the reconstructed images. In this work, the effects of the stepping errors and the dose fluctuations on the transmission, differential phase contrast, and dark-field images are theoretically derived and systematically summarized. A novel three-step iterative method is designed for image reconstruction in Talbot-Lau interferometry with phase-stepping errors and dose fluctuations. Phase distributions, phase-stepping errors, and dose fluctuation coefficients are iteratively updated via the least square method until the convergence criteria are met. Moire artifacts are mostly reduced via the proposed method in both the numerical simulations and experiments. The reconstructed images are highly coincident with the ground truth, which verifies the high accuracy of this method. The proposed algorithm is also compared with other moire artifacts reduction algorithms, which further demonstrates the high precision of this algorithm. This work is beneficial for reducing the strict requirements for the hardware system in the conventional Talbot-Lau interferometry, such as the high accuracy motorized stages and the X-ray tube with high stability, which is significant for advancing the X-ray phase contrast imaging towards the practical medical applications.(c) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据