4.6 Article

Depth of cure of 10 resin-based composites light-activated using a laser diode, multi-peak, and single-peak light-emitting diode curing lights

期刊

JOURNAL OF DENTISTRY
卷 122, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jdent.2022.104141

关键词

Resin-based composites; Polymerization; Light curing units; ISO 4049; Radiant exposure; Beam profile; Exposure reciprocity

资金

  1. MITACS [IT26826]
  2. Faculty of Dentistry, Dalhousie University
  3. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior-Brasil (CAPES) [001]

向作者/读者索取更多资源

This study evaluated the depth of cure (DOC) of ten resin-based composites (RBCs) cured with different light-curing units (LCUs) and exposure times. Results showed significant differences in the DOC achieved by different LCUs and composites. The study also found that the radiant exposure (RE) was the most critical factor in determining the DOC of these RBCs.
Objectives: To evaluate the depth of cure (DOC) of ten contemporary resin-based composites (RBCs), light-cured using different LCUs and exposure times. Methods: The power, radiant emittance, irradiance, radiant exposure (RE), and beam profiles from a laser (M, Monet), a multi-peak (V, Valo Grand), and single-peak (S, SmartLite Pro) LCU were measured. The DOC was measured using a 6-mm diameter metal mold and a solvent dissolution method to remove the uncured RBC. The length of the remaining RBC was divided by 2. The exposure times were: 1 s and 3 s for M, 10 s and 20 s for V, and 10 s and 20 s for S. Data were analyzed using: Bland-Altman distribution, Pearson's Correlation, and an artificial neural network (ANN) to establish the relative importance of the factors on the DOC (alpha=0.05; beta=0.2). Results: Significant differences were found in the DOC achieved by the different LCUs and composites. The laser LCU emitted the highest power, radiant emittance is used above and in the tables and delivered the highest irradiance. However, this LCU used for 1 s delivered the lowest RE and produced the shortest DOC in all ten RBCs. The ANN demonstrated that the RE is the most critical factor for the DOC. Bland-Altman comparisons showed that the DOCs achieved with the laser LCU used for 1 s were between 17 and 34% shorter than the other conditions. Conclusions: Although the laser LCU cured all 10 RBCs when used for 1 s, it produced the shallowest DOC, and some RBCs did not achieve their minimum DOC threshold. The RE and not the irradiance was the most important factor in determining the DOC of these 10 RBCs. Clinical significance: Despite delivering high power and irradiance, the laser used for l s delivered a lower radiant exposure than the conventional LCUs used for 10 s. This resulted in a shorter DOC.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据